Products
Aluminum Nitride Plate
Thermal Conductivity : 170-180 W/m.K
Density : 3.30 g/cm3
Color : Grey & Dark Grey
Max. Working Temperature : 1,500 degree C
Application : Chip Resistor, Power Modules, LED packages, General isolator

Aluminum nitride plate has the advantages of excellent electrical insulation, thermal conductivity, high temperature resistance, corrosion resistance, and matching with the thermal expansion coefficient of silicon. Aluminum nitride ceramic plate has become a new generation of large-scale integrated circuits, semiconductor module circuits and high-power devices. AlN ceramic plate is ideal for heat dissipation and packaging materials.
Popular Features
√ fast delivery | √ low thermal expansion | √ high thermal conductivity | √ high working temperature |
√ good metalization capacity | √ excellent electrical insulation | √ CTE close to that of Silicon (Si) | √ corrosion and erosion resistant |
▼ Bulk Density (g/cm3)
Specimens ID No. | 1 | 2 | 3 | 4 |
Test Value | 3.34 | 3.34 | 3.34 | 3.34 |
Mean value | 3.34 | |||
∆ Test Method: Refer to ISO 10545-3:2018 Ceramic tiles - Part 3: Determination of water absorption, apparent porosity, apparent relative density and bulk density / Specimens: 50mm×50mm×0.5mm, 4pcs | ||||
▼ Coefficient of Linear Expansion (10-6/°C)
Specimens ID No. | 1 | 2 | 3 |
Test Value | 3.4 | 3.4 | 3.4 |
Mean value | 3.4 | ||
| ∆ Test Method: Refer to ASTM D4535-13ɛ1 Standard Test Methods for Measurement of Thermal Expansion of Rock Using Dilatometer / Specimens: 50mm×10mm×0.5mm, 3pcs / Heating rate 1°C per min / Temperature range from room temperature to 100°C. | |||
▼ Thermal Conductivity (W/m‧K)
Test Result | 185.6 |
∆ Test Method: ISO 22007-2(2015) Plastics-Determination of thermal conductivity and thermal diffusivity Part 2: Transient plane heat source (Hot Disk) method / Specimens: 100mm×100mm×0.5mm, 2pcs / Test Conditioning: Sensor Type C4922 (radius 14.61 mm), Heating Power 2.5 W, Measurement Time 2 sec., Test temperature (23 ± 2) °C, Lab Environmental Conditions (25 ± 2) °C, (50 ± 10 ) % RH | |
▼ Flexural Strength (Mpa)
Test Result | 471 |
∆ Test Method: Refer to GB/T 9341-2008 and client's requirement / Specimen: 50mm×4.02mm×0.50mm / Testing speed: 0.5mm per minute / Span: 30mm | |
▼ Dielectric Breakdown Voltage & Dielectric Strength
Specimens ID No. | Specimen Thickness (mm) | Dielectric Breakdown Voltage (KV) | Dielectric Strength (KV/mm) |
1 | 1.03 | 19.45 | 18.88 |
2 | 1.03 | 18.66 | 18.12 |
3 | 1.03 | 17.88 | 17.36 |
4 | 1.03 | 18.26 | 17.73 |
5 | 1.04 | 17.49 | 16.82 |
Median | -- | 18.26 | 17.73 |
∆ Test Method: GB/T 1408.1-2016 Short-time (Rapid-rise) / Test Specimens: 100mm×100mm×1.0mm, 5pcs / Test Precondition: 23 ± 2 °C, 50 ± 5 % RH, 48 h / Test temperature: 23 ± 2 °C / Surround medium: 10# Transformer oil / Dissimilar electrode: lower electrode diameter 75 mm, upper electrode diameter 25 mm / Frequency of voltage application 50 Hz / Rate-of-rise 1000 V per second | |||
▼ Volume Resistivity
Specimens ID No. | Specimen Thickness (mm) | Volume Resistance Rv (Ω) | Volume Resistivity ρv (Ω·cm) |
1 | 0.54 | 5.96×1011 | 3.12×1014 |
2 | 0.53 | 3.48×1011 | 1.86×1014 |
3 | 0.53 | 5.38×1011 | 2.87×1014 |
4 | 0.53 | 5.16×1011 | 2.75×1014 |
5 | 0.54 | 4.29×1011 | 2.25×1014 |
Median | -- | 5.16×1011 | 2.75×1014 |
∆ Test Method: GB/T 1410-2006 / Specimens: 100mm×100mm×0.5mm, 5pcs / Test Condition: Precondition23 ± 2 °C, 50 ± 5 %RH, 48 h; Test electrode diameter 50 mm; Gap width 10.0 mm; Test voltage 500 Vdc; Electrification time 1 min. | |||
Applications

Hot Tags: aluminum nitride plate, China, suppliers, manufacturers, factory, wholesale, price, for sale